Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l
HomeHome > Products > Circuit Breakers > Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l
Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l

Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l

Overview Product Description 1.CJL1-125 Type B Residual Current Circuit Breaker (RCCB), suitable for rated voltage 230V
Overview
Basic Info.
Model NO. RCCB
Poles Number 2p and 4p
Type Circuit Breaker
Function RCCB
Certification CE
Fob Port Shanghai or Ningbo
Standards IEC61008-1, En61008-2-1
Transport Package Normal Export Package
Specification 2P, 4P
Trademark GSM
Origin Wenzhou China.
HS Code 85362000
Production Capacity 500000/Year
Product Description
Product Description

1.CJL1-125 Type B Residual Current Circuit Breaker (RCCB), suitable for rated voltage 230V at two poles, 400V at four poles, rated current n line 63A, when the person gets an electric shock or the grid leakage current exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply for protecting the safety of human body and electrical equipment can also be used for infrequent switching of circuits and infrequent starting of motors.
2.It complies with standard of IEC61008-1,EN61008-2-1
Product Advantages
1.Operating mechanism is plastic structure, operatingperformance is more stable and reliable than metalstructure. such as release force, mechanical life cycle.For environmental protection is better than metal typeand also the type is new generation mechanism.2.Inside all current-carrying parts: copper.3.All screws are with the plastic cover seal the holes,lt's move safety can not open the products in easy.4.A Big sizes transparent signboard can help user makesome special marks in the signboard area.5.The very new tripping structure make more safety

Product Parameters

Technical Data

StandardsIEC61008-1/IEC61008-2-1
Rated current16A,20A,25A,32A,40A,50A,63A
Rated voltage230~1P+N,400V~3P+N
Rated frequency50/60Hz
Number of pole2P,4P
Module size36mm
Circuit typeAC type,A type, B type
Breaking capacity6000A
Rated residual operating current10,30,100,300mA
Optimum operating temperature-5°C to 40°C
Terminal Tightening torque2.5~4N/m
Terminal Capacity(top)25mm²
Terminal Capacity(bottom)25mm²
Electro-mechanical endurance4000 cycles
Mounting35mm DinRail
Suitable BusbarPIN Busbar
Detailed Information

Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l-63 2pole


certification&company Profile

Residual Current Circuit Breaker, RCCB, ELCB, Electromagnetic AC Type RTF1l-63 2pole

More products